🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

NSComm SC APC to SC APC Duplex Single Mode Fiber Patch Cable, 2.0mm OFNR

Product image 1
Product image 2
Product image 3
Product image 4

NSComm SC APC to SC APC Duplex Single Mode Fiber Patch Cable, 2.0mm OFNR

NSComm SC APC to SC APC Duplex Single Mode Fiber Patch Cable, 2.0mm OFNR

Overview

The NSComm SC APC to SC APC Duplex Single Mode Fiber Patch Cable is a high-performance OS2 interconnect solution designed for long-distance, high-bandwidth applications across data centers, telecommunication rooms, enterprise networks, and backbone environments. Featuring SC APC duplex connectors on both ends with an angled 8° polish, this cable delivers ultra-low back reflection and low insertion loss, making it ideal for long-reach optical links and return-loss-sensitive systems such as DWDM, OTN, and high-speed Ethernet up to 400G.

Constructed with bend-insensitive G.657.A1 fiber and a slim 1.2mm riser-rated (OFNR) tight-buffered jacket, this duplex patch cable provides excellent flexibility, reduced attenuation under bending, and easier routing through dense trays and cable pathways. Its compact diameter enables high-density patching while maintaining mechanical durability and optical stability, making installation faster and more efficient in modern network environments.

Need assistance selecting optimal lengths, connector types, or polarity mapping for your SC APC links? Contact us now and our engineering team will help validate your design before deployment.

Key Specifications

Specification Details
Vendor Name NSComm
Product Type SC APC to SC APC Duplex Single Mode Fiber Patch Cable
Connector A SC APC Duplex
Connector B SC APC Duplex
Fiber Count 2 Fibers (Duplex)
Fiber Grade G.657.A1 (Compatible with G.652.D)
Fiber Mode OS2 9/125 μm
Wavelength 1310 nm / 1550 nm
Flame Rating Riser (OFNR)
Cable Outside Diameter (OD) 1.2 mm
Polarity A (Tx) to B (Rx)
Cable Type Tight-buffered
Min. Bend Radius (Optical Fiber) 10 mm
Min. Bend Radius (Fiber Cable) 20/10D (Dynamic/Static)
Connector Durability 1000 mating cycles
Tensile Strength 40/80 N (Long/Short Term)
Insertion Loss ≤ 0.30 dB
Return Loss ≥ 60 dB (APC)
Attenuation @ 1310 nm 0.4 dB/km
Attenuation @ 1550 nm 0.3 dB/km
Operating Temperature -10 to 70 °C (14 to 158 °F)
Storage Temperature -20 to 70 °C (-4 to 158 °F)
Applications 1G–400G Ethernet, SC-based panels, long-distance OS2 links, DWDM/OTN & optical backbones


Why Choose NSComm SC APC to SC APC Duplex OS2 Patch Cables?

  • Ultra-low reflection APC performance – 8° angled SC APC connectors provide ≥60 dB return loss, ideal for long-reach and DWDM applications.

  • Slim 1.2mm high-density design – Thin profile saves space on patch panels and improves airflow in dense racks.

  • Bend-insensitive G.657.A1 fiber – Reduces attenuation under tight bends, improving installation flexibility and system reliability.

  • Long-distance OS2 capability – Suitable for up to 10 km @ 1310 nm and 40 km @ 1550 nm transmission distances.

  • Riser-rated OFNR construction – Durable tight-buffered cable for safe use in riser spaces, racks, trays, and conduits.

Length Options

Standard stocked lengths:
Available in commonly used patch cord lengths for ODF-to-ODF, rack-to-rack, and equipment-to-panel connections.

Custom lengths:
Custom lengths, labeling, colors, and polarity options available to match your exact cabling architecture and deployment standards.

More Details

Quality Certifications

Do you have any question about the NSComm SC to SC APC Duplex Single Mode Fiber Patch Cable?

Please Chat with us now!

or leave us an message on [email protected]

Warranty

100% Low Price Guarantee

Network-switch.com provides high-quality products at low wholesale prices

100% Quality Assurance

All items are ORIGINAL and GENUINE only.
Item conditions are "New Sealed". They are fully tested by Certified CCIE / HCIE / RCNP Engineers.

Free Technical Support

Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.

100% Money Back Guarantee

You can contact our customer service team to exchange or return any product that you bought from us.

Standard Warranty Policy

Original New Sealed Enterprise Hardware: 3 Years
Original New Sealed Consumer Devices: 1 Year

The Support Contacts

If your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

Select Length
From $2.91

Original: $8.30

-65%
NSComm SC APC to SC APC Duplex Single Mode Fiber Patch Cable, 2.0mm OFNR

$8.30

$2.91

Product Information

Shipping & Returns

Description

Overview

The NSComm SC APC to SC APC Duplex Single Mode Fiber Patch Cable is a high-performance OS2 interconnect solution designed for long-distance, high-bandwidth applications across data centers, telecommunication rooms, enterprise networks, and backbone environments. Featuring SC APC duplex connectors on both ends with an angled 8° polish, this cable delivers ultra-low back reflection and low insertion loss, making it ideal for long-reach optical links and return-loss-sensitive systems such as DWDM, OTN, and high-speed Ethernet up to 400G.

Constructed with bend-insensitive G.657.A1 fiber and a slim 1.2mm riser-rated (OFNR) tight-buffered jacket, this duplex patch cable provides excellent flexibility, reduced attenuation under bending, and easier routing through dense trays and cable pathways. Its compact diameter enables high-density patching while maintaining mechanical durability and optical stability, making installation faster and more efficient in modern network environments.

Need assistance selecting optimal lengths, connector types, or polarity mapping for your SC APC links? Contact us now and our engineering team will help validate your design before deployment.

Key Specifications

Specification Details
Vendor Name NSComm
Product Type SC APC to SC APC Duplex Single Mode Fiber Patch Cable
Connector A SC APC Duplex
Connector B SC APC Duplex
Fiber Count 2 Fibers (Duplex)
Fiber Grade G.657.A1 (Compatible with G.652.D)
Fiber Mode OS2 9/125 μm
Wavelength 1310 nm / 1550 nm
Flame Rating Riser (OFNR)
Cable Outside Diameter (OD) 1.2 mm
Polarity A (Tx) to B (Rx)
Cable Type Tight-buffered
Min. Bend Radius (Optical Fiber) 10 mm
Min. Bend Radius (Fiber Cable) 20/10D (Dynamic/Static)
Connector Durability 1000 mating cycles
Tensile Strength 40/80 N (Long/Short Term)
Insertion Loss ≤ 0.30 dB
Return Loss ≥ 60 dB (APC)
Attenuation @ 1310 nm 0.4 dB/km
Attenuation @ 1550 nm 0.3 dB/km
Operating Temperature -10 to 70 °C (14 to 158 °F)
Storage Temperature -20 to 70 °C (-4 to 158 °F)
Applications 1G–400G Ethernet, SC-based panels, long-distance OS2 links, DWDM/OTN & optical backbones


Why Choose NSComm SC APC to SC APC Duplex OS2 Patch Cables?

  • Ultra-low reflection APC performance – 8° angled SC APC connectors provide ≥60 dB return loss, ideal for long-reach and DWDM applications.

  • Slim 1.2mm high-density design – Thin profile saves space on patch panels and improves airflow in dense racks.

  • Bend-insensitive G.657.A1 fiber – Reduces attenuation under tight bends, improving installation flexibility and system reliability.

  • Long-distance OS2 capability – Suitable for up to 10 km @ 1310 nm and 40 km @ 1550 nm transmission distances.

  • Riser-rated OFNR construction – Durable tight-buffered cable for safe use in riser spaces, racks, trays, and conduits.

Length Options

Standard stocked lengths:
Available in commonly used patch cord lengths for ODF-to-ODF, rack-to-rack, and equipment-to-panel connections.

Custom lengths:
Custom lengths, labeling, colors, and polarity options available to match your exact cabling architecture and deployment standards.

More Details

Quality Certifications

Do you have any question about the NSComm SC to SC APC Duplex Single Mode Fiber Patch Cable?

Please Chat with us now!

or leave us an message on [email protected]

Warranty

100% Low Price Guarantee

Network-switch.com provides high-quality products at low wholesale prices

100% Quality Assurance

All items are ORIGINAL and GENUINE only.
Item conditions are "New Sealed". They are fully tested by Certified CCIE / HCIE / RCNP Engineers.

Free Technical Support

Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.

100% Money Back Guarantee

You can contact our customer service team to exchange or return any product that you bought from us.

Standard Warranty Policy

Original New Sealed Enterprise Hardware: 3 Years
Original New Sealed Consumer Devices: 1 Year

The Support Contacts

If your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

NSComm SC APC to SC APC Duplex Single Mode Fiber Patch Cable, 2.0mm OFNR | Network-switch