🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

NSComm SC APC to FC APC Simplex Single Mode Fiber Patch Cable, 2.0mm OFNR

Product image 1
Product image 2
Product image 3
Product image 4

NSComm SC APC to FC APC Simplex Single Mode Fiber Patch Cable, 2.0mm OFNR

NSComm SC APC to FC APC Simplex Single Mode Fiber Patch Cable, 2.0mm OFNR

Overview

The NSComm SC APC to FC APC Simplex Single Mode Fiber Patch Cable is a high-performance OS2 interconnect designed for long-distance, point-to-point links across entrance facilities, telecommunications rooms, data centers, and lab or test environments. With an SC APC connector on one end and an FC APC connector on the other, this cable provides a reliable interface between SC-based patch panels or equipment and FC-based transmission systems that require secure, threaded terminations.

Equipped with bend-insensitive G.657.A1 fiber and a 2.0mm riser-rated (OFNR) tight-buffered jacket, this simplex patch cable delivers low insertion loss, ultra-high return loss, and robust mechanical durability. The angled APC polish (8°) on both ends minimizes back reflection, making the cable especially suitable for long-distance OS2 applications up to 10 km at 1310 nm or up to 40 km at 1550 nm, while reduced attenuation under bending and twisting helps simplify installation and ongoing maintenance.

Need help confirming SC–FC APC compatibility, link budget, or length selection? Contact us now and our team will help validate your design before deployment.

Key Specifications

Specification Details
Vendor Name NSComm
Product Type SC APC to FC APC Simplex Single Mode Fiber Patch Cable
Connector A SC APC Simplex
Connector B FC APC Simplex
Fiber Count 1 Fiber (Simplex)
Fiber Grade G.657.A1 (Compatible with G.652.D)
Fiber Mode OS2 9/125 μm
Wavelength 1310 nm / 1550 nm
RoHS Compliancy Status Compliant
Cable Type Tight-buffered
Cable Outside Diameter (OD) 2.0 mm
Flame Rating Riser (OFNR)
Min. Bend Radius (Optical Fiber) 10 mm
Min. Bend Radius (Fiber Cable) 10/5D (Dynamic/Static)
Connector Durability 1000 mating cycles
Tensile Strength 60/100 N (Long/Short Term)
Insertion Loss ≤ 0.30 dB
Return Loss ≥ 60 dB (APC)
Attenuation @ 1310 nm 0.4 dB/km
Attenuation @ 1550 nm 0.3 dB/km
Operating Temperature -10 to 70 °C (14 to 158 °F)
Storage Temperature -20 to 70 °C (-4 to 158 °F)
Recommended Distance @ 1310 nm Up to 10 km (application dependent)
Recommended Distance @ 1550 nm Up to 40 km (application dependent)
Applications 1G/10G/25G/40G/100G/400G Ethernet, SC panel to FC equipment, DWDM/OTN, DC/telecom links


Why Choose NSComm SC APC to FC APC Simplex OS2 Patch Cables?

  • APC-to-APC ultra-low reflection – 8° angled SC APC and FC APC connectors deliver very high return loss (≥60 dB) for sensitive long-reach links.

  • Interoperability between SC and FC – Ideal for bridging SC-based panels or ODFs to FC-based transport shelves, amplifiers, or test gear.

  • Long-distance OS2 single mode capability – Supports up to 10 km @ 1310 nm and 40 km @ 1550 nm for extended reach deployments.

  • Bend-insensitive G.657.A1 fiber – Reduced attenuation under bends and twists simplifies routing in dense cable management environments.

  • Riser-rated 2.0mm construction – Tight-buffered OFNR jacket provides durability and easy handling in riser spaces, racks, and conduits.

Length Options

Standard stocked lengths:
Available in a variety of common simplex lengths suited for equipment-to-frame, panel-to-panel, and long-reach patching in telecom rooms and data centers.

Custom lengths:
Custom lengths, jacket colors, labeling, and connector orientation options are available on request to align with your exact rack layout, plant design, and routing paths.

More Details

Quality Certifications

Do you have any question about the NSComm SC to FC Simplex Single Mode Fiber Patch Cable?

Please Chat with us now!

or leave us an message on [email protected]

Warranty

100% Low Price Guarantee

Network-switch.com provides high-quality products at low wholesale prices

100% Quality Assurance

All items are ORIGINAL and GENUINE only.
Item conditions are "New Sealed". They are fully tested by Certified CCIE / HCIE / RCNP Engineers.

Free Technical Support

Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.

100% Money Back Guarantee

You can contact our customer service team to exchange or return any product that you bought from us.

Standard Warranty Policy

Original New Sealed Enterprise Hardware: 3 Years
Original New Sealed Consumer Devices: 1 Year

The Support Contacts

If your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

$1.26

Original: $3.60

-65%
NSComm SC APC to FC APC Simplex Single Mode Fiber Patch Cable, 2.0mm OFNR

$3.60

$1.26

Product Information

Shipping & Returns

Description

Overview

The NSComm SC APC to FC APC Simplex Single Mode Fiber Patch Cable is a high-performance OS2 interconnect designed for long-distance, point-to-point links across entrance facilities, telecommunications rooms, data centers, and lab or test environments. With an SC APC connector on one end and an FC APC connector on the other, this cable provides a reliable interface between SC-based patch panels or equipment and FC-based transmission systems that require secure, threaded terminations.

Equipped with bend-insensitive G.657.A1 fiber and a 2.0mm riser-rated (OFNR) tight-buffered jacket, this simplex patch cable delivers low insertion loss, ultra-high return loss, and robust mechanical durability. The angled APC polish (8°) on both ends minimizes back reflection, making the cable especially suitable for long-distance OS2 applications up to 10 km at 1310 nm or up to 40 km at 1550 nm, while reduced attenuation under bending and twisting helps simplify installation and ongoing maintenance.

Need help confirming SC–FC APC compatibility, link budget, or length selection? Contact us now and our team will help validate your design before deployment.

Key Specifications

Specification Details
Vendor Name NSComm
Product Type SC APC to FC APC Simplex Single Mode Fiber Patch Cable
Connector A SC APC Simplex
Connector B FC APC Simplex
Fiber Count 1 Fiber (Simplex)
Fiber Grade G.657.A1 (Compatible with G.652.D)
Fiber Mode OS2 9/125 μm
Wavelength 1310 nm / 1550 nm
RoHS Compliancy Status Compliant
Cable Type Tight-buffered
Cable Outside Diameter (OD) 2.0 mm
Flame Rating Riser (OFNR)
Min. Bend Radius (Optical Fiber) 10 mm
Min. Bend Radius (Fiber Cable) 10/5D (Dynamic/Static)
Connector Durability 1000 mating cycles
Tensile Strength 60/100 N (Long/Short Term)
Insertion Loss ≤ 0.30 dB
Return Loss ≥ 60 dB (APC)
Attenuation @ 1310 nm 0.4 dB/km
Attenuation @ 1550 nm 0.3 dB/km
Operating Temperature -10 to 70 °C (14 to 158 °F)
Storage Temperature -20 to 70 °C (-4 to 158 °F)
Recommended Distance @ 1310 nm Up to 10 km (application dependent)
Recommended Distance @ 1550 nm Up to 40 km (application dependent)
Applications 1G/10G/25G/40G/100G/400G Ethernet, SC panel to FC equipment, DWDM/OTN, DC/telecom links


Why Choose NSComm SC APC to FC APC Simplex OS2 Patch Cables?

  • APC-to-APC ultra-low reflection – 8° angled SC APC and FC APC connectors deliver very high return loss (≥60 dB) for sensitive long-reach links.

  • Interoperability between SC and FC – Ideal for bridging SC-based panels or ODFs to FC-based transport shelves, amplifiers, or test gear.

  • Long-distance OS2 single mode capability – Supports up to 10 km @ 1310 nm and 40 km @ 1550 nm for extended reach deployments.

  • Bend-insensitive G.657.A1 fiber – Reduced attenuation under bends and twists simplifies routing in dense cable management environments.

  • Riser-rated 2.0mm construction – Tight-buffered OFNR jacket provides durability and easy handling in riser spaces, racks, and conduits.

Length Options

Standard stocked lengths:
Available in a variety of common simplex lengths suited for equipment-to-frame, panel-to-panel, and long-reach patching in telecom rooms and data centers.

Custom lengths:
Custom lengths, jacket colors, labeling, and connector orientation options are available on request to align with your exact rack layout, plant design, and routing paths.

More Details

Quality Certifications

Do you have any question about the NSComm SC to FC Simplex Single Mode Fiber Patch Cable?

Please Chat with us now!

or leave us an message on [email protected]

Warranty

100% Low Price Guarantee

Network-switch.com provides high-quality products at low wholesale prices

100% Quality Assurance

All items are ORIGINAL and GENUINE only.
Item conditions are "New Sealed". They are fully tested by Certified CCIE / HCIE / RCNP Engineers.

Free Technical Support

Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.

100% Money Back Guarantee

You can contact our customer service team to exchange or return any product that you bought from us.

Standard Warranty Policy

Original New Sealed Enterprise Hardware: 3 Years
Original New Sealed Consumer Devices: 1 Year

The Support Contacts

If your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

NSComm SC APC to FC APC Simplex Single Mode Fiber Patch Cable, 2.0mm OFNR | Network-switch