🚚 Free Worldwide Shipping on All Orders!Shop Now
HomeStore

NSComm MPO 16F APC to 8xLC UPC Duplex Harness Cables, 16 Fibers, Singlemode (OS2, G.657.A1), OFNR, Crossover

Product image 1

NSComm MPO 16F APC to 8xLC UPC Duplex Harness Cables, 16 Fibers, Singlemode (OS2, G.657.A1), OFNR, Crossover

NSComm MPO 16F APC to 8xLC UPC Duplex Harness Cables, 16 Fibers, Singlemode (OS2, G.657.A1), OFNR, Crossover

Overview

The NSComm MPO 16F APC to 8xLC UPC Duplex harness cable is a high-density single mode breakout solution engineered for next-generation 400G/800G data center networks. With one 16-fiber MPO-16 APC (Female) trunk breaking out to eight LC UPC duplex connectors, this harness provides sixteen active fibers for connecting switches, servers, and patch panels that still rely on LC interfaces while supporting OS2 G.657.A1 bend-insensitive performance.

Factory-terminated and fully tested, the MPO–LC harness ensures verified low insertion loss and high return loss to maintain optical integrity in large-scale distributed compute and storage environments. Designed for seamless migration from duplex-based 50/100G Ethernet to parallel 400/800G Ethernet architectures, this harness is ideal for high-density racks, structured cabling systems, equipment rooms, and telecommunication rooms where space optimization and clean cable management are essential.

Need help confirming crossover polarity or mapping to your 400G/800G transceivers? Contact us now, our engineering team can validate compatibility before deployment.

Key Specifications

Specification Details
Vendor Name NSComm
Product Type MPO 16F APC to 8xLC UPC Duplex Singlemode Harness Cable
Connector A MPO-16 APC Female (Pinless) with Offset Key, Low Loss
Connector B 8 × LC UPC Duplex connectors
Polish Type APC (MPO) to UPC (LC)
Glass Fiber G.657.A1 bend-insensitive single mode
Fiber Mode OS2 9/125 μm
Wavelength 1310 nm / 1550 nm
Fiber Count 16 Active Fibers (8×LC duplex)
Polarity Crossover
Cable Outside Diameter (OD) 3.0 mm (trunk, typical)
Breakout Outside Diameter (OD) 2.0 mm (LC legs, typical)
Breakout Length 0.5 m (typical)
Cable Jacket Riser-rated, OFNR
Minimum Bend Radius 10 mm
MPO Connector Insertion Loss ≤ 0.35 dB (Typ. 0.15 dB)
MPO Connector Return Loss ≥ 60 dB
LC Connector Insertion Loss ≤ 0.20 dB
LC Connector Return Loss ≥ 50 dB
Attenuation @ 1310 nm ≤ 0.32 dB/km
Attenuation @ 1550 nm ≤ 0.18 dB/km
Long-term Tensile Load 80 N
Short-term Tensile Load 240 N
Operating Temperature -10 to 60 °C (14 to 140 °F)
Storage Temperature -10 to 70 °C (14 to 158 °F)
Standards Compliance MPO interface standards, OS2, RoHS compliant
Applications Duplex-to-parallel migration, 50G/100G to 400G/800G, high-density LC breakout in racks


Why Choose NSComm MPO 16F to 8xLC UPC Duplex Harness Cables?

  • High-density breakout design – One MPO-16 trunk to eight LC duplex legs enables large port fan-outs while minimizing cable clutter.

  • Ideal for 50/100G → 400/800G migration – Designed for transitions from duplex LC links to parallel optics-based architectures.

  • Low insertion loss performance – Factory-terminated MPO and LC connectors ensure tight optical budgets across all links.

  • Bend-insensitive OS2 G.657.A1 fiber – Maintains signal integrity in tight routing and dense pathways within racks.

  • Crossover polarity for correct channel mapping – Pre-engineered polarity simplifies LC port alignment and reduces errors.

  • Riser-rated OFNR construction – Appropriate for in-cabinet routing and structured cabling in enterprise and cloud data centers.

Length Options

Standard stocked lengths:
Available in optimized lengths for top-of-rack, end-of-row, and structured cabling scenarios with balanced trunk and breakout leg lengths.

Custom lengths:
Custom trunk lengths, breakout leg lengths, LC labeling, and connector configurations are available upon request to match your switching layout and rack-level cable design.

More Details

Quality Certifications

Do you have any question about the NSComm MPO-16 APC to 8xLC UPC Harness Cable?

Please Chat with us now!

or leave us an message on [email protected]

Warranty

100% Low Price Guarantee

Network-switch.com provides high-quality products at low wholesale prices

100% Quality Assurance

All items are ORIGINAL and GENUINE only.
Item conditions are "New Sealed". They are fully tested by Certified CCIE / HCIE / RCNP Engineers.

Free Technical Support

Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.

100% Money Back Guarantee

You can contact our customer service team to exchange or return any product that you bought from us.

Standard Warranty Policy

Original New Sealed Enterprise Hardware: 3 Years
Original New Sealed Consumer Devices: 1 Year

The Support Contacts

If your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

Select Length
From $186.00
NSComm MPO 16F APC to 8xLC UPC Duplex Harness Cables, 16 Fibers, Singlemode (OS2, G.657.A1), OFNR, Crossover
$186.00

Product Information

Shipping & Returns

Description

Overview

The NSComm MPO 16F APC to 8xLC UPC Duplex harness cable is a high-density single mode breakout solution engineered for next-generation 400G/800G data center networks. With one 16-fiber MPO-16 APC (Female) trunk breaking out to eight LC UPC duplex connectors, this harness provides sixteen active fibers for connecting switches, servers, and patch panels that still rely on LC interfaces while supporting OS2 G.657.A1 bend-insensitive performance.

Factory-terminated and fully tested, the MPO–LC harness ensures verified low insertion loss and high return loss to maintain optical integrity in large-scale distributed compute and storage environments. Designed for seamless migration from duplex-based 50/100G Ethernet to parallel 400/800G Ethernet architectures, this harness is ideal for high-density racks, structured cabling systems, equipment rooms, and telecommunication rooms where space optimization and clean cable management are essential.

Need help confirming crossover polarity or mapping to your 400G/800G transceivers? Contact us now, our engineering team can validate compatibility before deployment.

Key Specifications

Specification Details
Vendor Name NSComm
Product Type MPO 16F APC to 8xLC UPC Duplex Singlemode Harness Cable
Connector A MPO-16 APC Female (Pinless) with Offset Key, Low Loss
Connector B 8 × LC UPC Duplex connectors
Polish Type APC (MPO) to UPC (LC)
Glass Fiber G.657.A1 bend-insensitive single mode
Fiber Mode OS2 9/125 μm
Wavelength 1310 nm / 1550 nm
Fiber Count 16 Active Fibers (8×LC duplex)
Polarity Crossover
Cable Outside Diameter (OD) 3.0 mm (trunk, typical)
Breakout Outside Diameter (OD) 2.0 mm (LC legs, typical)
Breakout Length 0.5 m (typical)
Cable Jacket Riser-rated, OFNR
Minimum Bend Radius 10 mm
MPO Connector Insertion Loss ≤ 0.35 dB (Typ. 0.15 dB)
MPO Connector Return Loss ≥ 60 dB
LC Connector Insertion Loss ≤ 0.20 dB
LC Connector Return Loss ≥ 50 dB
Attenuation @ 1310 nm ≤ 0.32 dB/km
Attenuation @ 1550 nm ≤ 0.18 dB/km
Long-term Tensile Load 80 N
Short-term Tensile Load 240 N
Operating Temperature -10 to 60 °C (14 to 140 °F)
Storage Temperature -10 to 70 °C (14 to 158 °F)
Standards Compliance MPO interface standards, OS2, RoHS compliant
Applications Duplex-to-parallel migration, 50G/100G to 400G/800G, high-density LC breakout in racks


Why Choose NSComm MPO 16F to 8xLC UPC Duplex Harness Cables?

  • High-density breakout design – One MPO-16 trunk to eight LC duplex legs enables large port fan-outs while minimizing cable clutter.

  • Ideal for 50/100G → 400/800G migration – Designed for transitions from duplex LC links to parallel optics-based architectures.

  • Low insertion loss performance – Factory-terminated MPO and LC connectors ensure tight optical budgets across all links.

  • Bend-insensitive OS2 G.657.A1 fiber – Maintains signal integrity in tight routing and dense pathways within racks.

  • Crossover polarity for correct channel mapping – Pre-engineered polarity simplifies LC port alignment and reduces errors.

  • Riser-rated OFNR construction – Appropriate for in-cabinet routing and structured cabling in enterprise and cloud data centers.

Length Options

Standard stocked lengths:
Available in optimized lengths for top-of-rack, end-of-row, and structured cabling scenarios with balanced trunk and breakout leg lengths.

Custom lengths:
Custom trunk lengths, breakout leg lengths, LC labeling, and connector configurations are available upon request to match your switching layout and rack-level cable design.

More Details

Quality Certifications

Do you have any question about the NSComm MPO-16 APC to 8xLC UPC Harness Cable?

Please Chat with us now!

or leave us an message on [email protected]

Warranty

100% Low Price Guarantee

Network-switch.com provides high-quality products at low wholesale prices

100% Quality Assurance

All items are ORIGINAL and GENUINE only.
Item conditions are "New Sealed". They are fully tested by Certified CCIE / HCIE / RCNP Engineers.

Free Technical Support

Our FREE Expert Consultancy Support is over the phone, by chat, by email or by login remotely.

100% Money Back Guarantee

You can contact our customer service team to exchange or return any product that you bought from us.

Standard Warranty Policy

Original New Sealed Enterprise Hardware: 3 Years
Original New Sealed Consumer Devices: 1 Year

The Support Contacts

If your NSComm products failed, you must contact your sales representative to verify product failure. If the problem still can't correct by remote support methods i.e. email or phone support, the RMA procedure will issue.

NSComm MPO 16F APC to 8xLC UPC Duplex Harness Cables, 16 Fibers, Singlemode (OS2, G.657.A1), OFNR, Crossover | Network-switch